DECTRIS® MYTHEN2 strip detectors have transformed high-resolution X-ray diffraction, scattering, and spectroscopy measurements by giving them another dimension: time. Renowned for its narrow strip and sharp point-spread function, MYTHEN2 X introduces a 1,000-Hz frame rate with a 24-bit dynamic range for any number of modules. This opens up new domains of time-resolved and in situ studies.
The Detector Control System 4 (DCS4), with electronic gating and an external trigger, allows for tailor-made multimodular solutions and full synchronization of the detector with other systems. The time dimension, however, does not compromise data quality or system flexibility: we guarantee noise-free detection even for long exposure times. Additionally, the modules’ optional vacuum compatibility opens up new possibilities for X-ray spectroscopy applications.
- Fast & accurate: these detectors offer noise-free detection over a range of X-ray energies, with frame rates up to 1,000 Hz and a 24-bit dynamic range.
- Modular & compatible: individual modules are easy to combine into large multimodular systems. The detectors also offer straightforward synchronization with other systems and optional vacuum capability.
- Reliable: detector performance is always stable. Delivery terms are guaranteed, thanks to streamlined industrial production and top-notch support.
Detectors
MYTHEN2 X 1K
These microstrip photon-counting X-ray detectors offer the ultimate speed and resolution for all time-resolved applications.
MYTHEN2 X 1D
These are the smallest detectors in DECTRIS’ portfolio that embody all the advantages of single-photon-counting technologies.
Detector Specifications*
MYTHEN2 X 1K | MYTHEN2 X 1D | |
---|---|---|
Strip width [µm ] |
50 |
50 |
Strip height [mm ] |
8 |
8 (450 μm only) |
Active area (W x H) [mm² ] |
64 × 8 |
32 x 8 (450) |
Energy range (depending on the sensor thickness) [keV ] |
5 - 40 (320) |
4 - 40 (320) |
Threshold range (depending on the sensor thickness) [keV ] |
4.5 - 20 (320) |
3.5 - 20 (320) |
Frame rate (max.) [Hz ] |
1,000 |
1,000 |
Count rate (max.) [ph/s/strip ] |
10⁷ |
10⁷ |
Readout time [µs ] |
89 |
89 |
Strips per module [strips ] |
1,280 |
640 |
Sensor material |
Silicon (Si) |
Silicon (Si) |
Sensor thickness [µm ] |
320, 450, or 1,000 |
320 or 450 |
Point-spread function [strips ] |
1 |
1 |
Vacuum compatibility |
Optional |
Optional |
Module dimensions (W x H x D) [mm³ ] |
70 x 62 x 22 |
36 x 62 x 22 |
Cooling method |
Air |
Air |
*All specifications are subject to change without notice.
Key Contact
Techniques
X-ray diffraction
Patterns with both weak and intense reflections are no challenge for the high dynamic range of DECTRIS strip detectors.
Read moreSpectroscopy
The combination of single-photon sensitivity with zero background noise enhances even the most advanced spectroscopic techniques.
Read moreRequest a quote
To get more information for a tender or learn more about purchasing a DECTRIS MYTHEN2® X-ray detector for synchrotron beamlines, reach out to us
Want to know more?
We are happy to answer any questions about us, our detectors, or the process of integrating our detectors into your experimental setup.
Need support?
Our Support team is here to answer your questions and help you take full advantage of your detector.